APC BR1500MS
Back UPS PRO BR 1500VA, SineWave, 10 Outlets, 2 USB Charging Ports, AVR, LCD interface
Back UPS PRO BR 1500VA, SineWave, 10 Outlets, 2 USB Charging Ports, AVR, LCD interface
| Cables Included: |
Power cable 1.83 m ¦ Coax cable ¦ USB cable |
| Circuit Protection: |
Circuit breaker |
| Compliant Standards: |
NOM, RoHS, REACH, CEC, TUV C, DOE |
| Dataline Surge Protection: |
Network - RJ-45 - 1 input line / 1 output line ¦ Coaxial - 1 input line / 1 output line |
| Depth: |
36.8 cm |
| Device Type: |
UPS - external |
| ENERGY STAR: |
Yes |
| Enclosure Colour: |
Black |
| Equipment Protection Value: |
500000 US Dollars |
| Features: |
Audible alarm, LCD display, Automatic Voltage Regulation (AVR), automatic self-test |
| Frequency Provided: |
60 Hz ± 3Hz |
| Frequency Required: |
60 Hz ± 3Hz |
| Height: |
26 cm |
| Humidity Range Operating: |
0 - 95% (non-condensing) |
| Input Connectors: |
1 x power NEMA 5-15P |
| Input Voltage: |
AC 120 V |
| Input Voltage Range: |
AC 88 - 147 V |
| Interfaces: |
1 x management |
| Manufacturer: |
APC Schneider |
| Max Electric Current: |
12 A |
| Max Operating Temperature: |
40 °C |
| Min Operating Temperature: |
0 °C |
| Output Voltage: |
AC 120 V 60 Hz |
| Output Waveform: |
Sinewave |
| Power Capacity: |
900 Watt / 1500 VA |
| Power Output Connectors Details: |
4 x power NEMA 5-15R (surge) ¦ 6 x power NEMA 5-15R (UPS and surge) ¦ 1 x 4 pin USB Type A ¦ 1 x 24 pin USB-C |
| Quantity: |
1 |
| Recharge Time: |
16 hours |
| Remote Management Interface: |
USB |
| Run Time (Up To): |
4.1 min at full load ¦ 14.5 min at half load ¦ 5.4 min at 800 Watts ¦ 7.1 min at 700 Watts ¦ 9.3 min at 600 Watts ¦ 12.4 min at 500 Watts ¦ 17.1 min at 400 Watts ¦ 24.8 min at 300 Watts ¦ 39.6 min at 200 Watts ¦ 77 min at 100 Watts ¦ 131 min at 50 Watts |
| Shipping Depth: |
48.2 cm |
| Shipping Height: |
35.87 cm |
| Shipping Weight: |
14.2 kg |
| Shipping Width: |
22.3 cm |
| Sound Emission: |
45 dBA |
| Surge Energy Rating: |
1080 Joules |
| Surge Suppression: |
Yes |
| Technology: |
Lead Acid |
| Transfer Time: |
8 ms |
| UPS Technology: |
Line interactive |
| Version: |
original |
| Weight: |
12.5 kg |
| Width: |
10 cm |
| GPSR - economic actor: |
Schneider Electric GmbH, Deutschland, Gothaer Str. 29, Ratingen, 40880, esupport.emeade @ schneider-electric.com |
| GPSR - product manufacturer: |
Schneider Electric GmbH, Deutschland, Gothaer Str. 29, Ratingen, 40880, esupport.emeade @ schneider-electric.com |
| GPSR - EU responsible person: |
Schneider Electric GmbH, Deutschland, Gothaer Str. 29, Ratingen, 40880, esupport.emeade @ schneider-electric.com |
| Warnings: |
Warnings UPS Systems & Power Distribution International.pdf |
| Safety instructions: |
Safety instructions UPS Systems & Power Distribution International.pdf |